AI summary · may contain errors
An AI-powered wearable ring using all-optical dermal activity sensing achieves 92.3% binary accuracy for stress-related classification, outperforming electrode-based EDA at 77.95%.
- Open access
Moving in medRxiv, Hypertension, Arteriosclerosis, Thrombosis, and Vascular Biology, Nature Cardiovascular Research, Nature Communications, Science Advances, American Journal of Respiratory and Critical Care Medicine and Nature Biomedical Engineering.
Rebuilt
Nothing in this topic has moved yet this week.
Newest first · last 60 days
AI summary · may contain errors
An AI-powered wearable ring using all-optical dermal activity sensing achieves 92.3% binary accuracy for stress-related classification, outperforming electrode-based EDA at 77.95%.
AI summary · may contain errors
A low-cost compact peripheral pulse sensor captured pulse waveform morphology with reliable beat-to-beat tracking across vascular-tree sites, preserving temporal trends despite feature offsets.
AI summary · may contain errors
In adults undergoing noncardiac surgery, intraoperative hypotension is linked to higher odds of cuff blood pressure inaccuracy, with adjusted odds ratio 1.45 versus normal MAP (≥65 mm Hg).
AI summary · may contain errors
CHW-coordinated home blood pressure monitoring in rural Kenya and The Gambia shows age-standardised sensitivity of 82.6% and 68.7% with specificity of 82.4% and 83.5% versus daytime ABPM.
AI summary · may contain errors
Black participants in MESA and SHHS had 21% and 20% lower proportions of airflow-defined obstructive events meeting the ≥4% desaturation criterion than White participants.
AI summary · may contain errors
Wearable sleep health technologies can measure sleep with high sensitivity but lower specificity for wake detection, with some consumer devices matching research-grade actigraphy and headband EEG nearing polysomnography-level staging.
AI summary · may contain errors
In a community-based cohort of adults older than 65 years, cf-PWV predicted major adverse cardiovascular events better than ba-PWV, with hazard ratios of 1.12 and 1.16.
AI summary · may contain errors
An all-fiber wireless auscultation garment captured deep-body cardiopulmonary sounds in 10 heart-failure patients and 20 neonates, enabling high-fidelity, noise-suppressed recording.
AI summary · may contain errors
A multimodal steerable filamentary bioelectronic probe in a sheep fetal surgery model monitored fetal bradycardia, hypoxia, and hypothermia during fetoscopic procedures.
AI summary · may contain errors
A monolithic capacitive pressure sensor array with co-integrated electrodes achieves 30 Hz full-body pressure mapping using a 2911-cell (1.7 m by 1.0 m) design with high linearity (R 2 = 0.994).
AI summary · may contain errors
Universal Coordinate (UC) combined with Dynamic Diffusion Maps (DDMap) yields an ABP-derived dynamics index that is significantly correlated with clinical outcomes in surgical databases.
AI summary · may contain errors
A bioresorbable, metal-free molecular magnet from graphitic carbon nitride achieves metallic-level ferromagnetism and enables continuous untethered multi-organ monitoring in porcine models.
AI summary · may contain errors
PulseOx-FM, trained on 6,995,558 pulse oximetry segments from 10,704 adults’ overnight sleep recordings, significantly outperformed existing feature methods and predicted 71 phenotypic targets beyond age.
AI summary · may contain errors
An intrinsically flexible, chiral inorganic piezoelectric subnanowire, ZnBiPMo 12, shows a piezoelectric coefficient of 24.9 pC/N and enables sensitive PE-skin detection of 0.045–0.319 N pressures.
AI summary · may contain errors
Wearable cardiovascular monitoring is shifting from intermittent checks to longitudinal surveillance, with AI-enabled extraction of clinically meaningful insights across heart rhythm, heart rate variability, and blood pressure.
AI summary · may contain errors
A biological geometry-aware AI framework predicts obstructive sleep apnea severity using multifractal coupling features, achieving area-under-the-curve values exceeding 0.91 across five heterogeneous cohorts of more than 35,000 subjects.
Journals this month
Topics moving, week to 17 Nov 2026
By field