A lightweight, interpretable MATLAB/Simulink ECG pipeline detects premature ventricular contractions in MIT-BIH with 71.43% sensitivity, 81.63% precision, and 76.19% F1 using +/-100 ms matching.
- Why it matters: Reliable ECG preprocessing and abnormal-event detection must stay interpretable and computationally light, while addressing the need to quantify performance limits on real annotated recordings.
- What they did: The system filters and processes ECG, detects QRS and R peaks, estimates heart rate, classifies rhythm, then flags PVCs using fixed rule logic from an RR-interval ratio and a QRS-energy ratio.
- The result: On nine held-out non-overlapping 10-s windows (56 expert-annotated PVCs from Records 106, 119, and 200), it produced 40 true positives, 9 false positives, and 16 false negatives, and achieved 94.39% R-peak sensitivity with 16.91 ms mean absolute timing error.