Lay raters using a pictorial blood loss assessment chart on photographs captured only 62% of alkaline hematin–measured menstrual blood volume, with heavy-cycle sensitivity of 47.1%.
- Why it matters: Pictorial charts are widely used, but their accuracy and person-to-person consistency against alkaline hematin are uncertain, especially for identifying heavy menstrual bleeding.
- What they did: In an online cross-sectional reliability study, 69 women rated photographs of 117 used pads from eight alkaline-hematin–validated cycles, with 44 repeating ratings about 2 weeks later.
- The result: Estimates systematically underestimated blood loss (mean bias −44.1 ml) and varied substantially between raters and sessions (between-rater SD 18.4 ml; within-rater SD 10.7 ml), despite high agreement statistics (Krippendorff’s alpha 0.86).
The findingWhy it mattersWhat they didThe result