A two-compartment 13C flux model fitted 41 of 45 mouse liver perfusion datasets, whereas a one-compartment model failed, with malate/TCA intermediates driving the mismatch.
- Why it matters: Global viability metrics during normothermic machine perfusion miss intracellular metabolic detail, limiting mechanistic assessment of donor liver function.
- What they did: Mouse livers underwent staged ex vivo perfusion with serial lobectomy and 13C tracers ([U-13C3]lactate, [U-13C3]pyruvate, [U-13C6]glucose), then compartment-specific fluxes were inferred using intracellular metabolite isotopomers as constraints.
- The result: Flux partitioning between compartments depended on nutritional state more than perfusate glucose, and glucose-fragment and two-compartment estimates correlated (R2 = 0.68–0.89), supporting simplified models for quantitative perfusion assessment.