medRxivJClub
Same pipelines, different answers: how evaluation design shapes EEG seizure prediction
medRxiv · · Preprint · Open access
song, Pedersen + 1 more
Abstract ↗AI summary
The abstract is read at the publisher; the summary is JClub's.
In CHB-MIT scalp EEG seizure prediction, evaluation design dominates architecture: PSD+LDA ranges from AUC 0.815 with random window allocation to 0.572 with intact preictal blocks held out.
- Why it matters: Reported accuracies can look clinically useful, but they may reflect how test windows are separated from training rather than true generalization.
- What they did: Five fixed seizure-prediction pipelines were run on CHB-MIT with different subject- and within-patient partitioning, including a within-patient split that kept preictal blocks intact and a random window allocation; window manifests and partitions were released.
- The result: With whole-subject holdout, all pipelines stayed near chance (mean AUC 0.527–0.553), and an index-based within-patient split leaked raw EEG across train-test boundaries in all ten eligible cases.
The findingWhy it mattersWhat they didThe result