A single-IMU visual biofeedback system using Lower Limb Trajectory Error (LLTE) produced systematic stance-phase knee kinematic changes under flexed-knee targets in 20 able-bodied adults.
- Why it matters: Multi-sensor, high-dimensional gait feedback can hinder routine clinical use, so a simpler wearable-derived error signal is needed to support interpretable retraining.
- What they did: Participants walked on a treadmill under flexed-knee and extended-knee targets with corrected versus uncorrected LLTE feedback; LLTE was computed in real time from knee-position and shank-orientation trajectories across stance.
- The result: LLTE and stance-phase knee kinematics changed systematically with the flexed-knee target, while temporal error-reduction patterns did not differ reliably by feedback formulation; multivariate multiscale sample entropy (MSMVSE) was higher during feedback-task than normal walking across both targets and formulations.